Abstract

BackgroundSeveral studies have compared nasal swabs to the more invasive nasopharyngeal aspirate (NPA) for detection of respiratory viruses. Mostly, the comparisons have been performed on immunocompetent children with upper respiratory tract symptoms. The results range from a relatively poor sensitivity for the swabs to an even higher sensitivity than for the NPA. We aimed to investigate the sensitivity of a flocked nasal swab (fNS) on immunocompromised adults with febrile neutropenia.MethodsDuring 16 months, adults with a hematological disorder presenting with febrile neutropenia were enrolled in the study. Paired samples of the fNS and NPA were collected in the outer part of the nasal cavity and the nasopharynx, respectively. The samples were analyzed regarding a panel of 15 respiratory viruses by means of quantitative polymerase chain reaction. Furthermore, as an indirect measure of cell yield by either method, the copy number of the human beta actin gene was also determined. Cohen's kappa was calculated as a measure of agreement of the results obtained from either method. Wilcoxon signed-rank test was used for comparison of cell yield.ResultsA total of 98 paired samples from a total of 89 patients were collected. Twenty of the pairs had virus detected in at least one of the specimens; 11 in both, 7 in NPA only, and 2 in fNS only. For the fNS, the overall sensitivity for any virus and for rhinovirus only was 65% and 78%, respectively. NPA was significantly superior to the fNS in collecting epithelial cells.ConclusionWe found the overall sensitivity of 65% to be too low to replace NPA with this sampling technique in this patient category.

Highlights

  • Several studies have compared nasal swabs to the more invasive nasopharyngeal aspirate (NPA) for detection of respiratory viruses

  • NPA [1,4,9], the primary objective of this study was to determine the sensitivity of detecting respiratory viruses in immunocompromised adults using a flocked nasal swab in the outer part of the nose cavity compared to NPA

  • A total of 98 episodes of febrile neutropenia occurring in 89 patients were included in the study

Read more

Summary

Introduction

Several studies have compared nasal swabs to the more invasive nasopharyngeal aspirate (NPA) for detection of respiratory viruses. A number of studies have compared different sampling techniques for detection of viruses in the upper respiratory tract in immunocompetent children [1,2,3,4,5,6,7,8,9,10,11,12,13,14]. NPA [1,4,9], the primary objective of this study was to determine the sensitivity of detecting respiratory viruses in immunocompromised adults using a flocked nasal swab (fNS) in the outer part of the nose cavity compared to NPA

Objectives
Methods
Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call