Abstract

Lateral torsional buckling reduces the moment capacity of steel I-girders. To redress this weakening, one approach is to replace the conventional plate flange with a rectangular tube, which has higher lateral stiffness and is thus helpful to resist lateral buckling. At the same time, web openings are introduced to enable services to pass through, but this causes a reduction in strength. Girders with tubular flange plus web openings have not yet been discussed in the literature. In this paper, finite-element method modelling is used to fill this gap, studying different slenderness classifications, as well as parameters such as size of web openings, spacing and location. The results for a solid web are found to be more comparable to the Eurocodes for steel structures than the American Institute of Steel Construction codes, enabling good prediction of the flexural capacity. By introducing web openings, the flexural capacity is reduced by 10–20%, closer to the higher side for openings with large diameters located near the compression flange. Openings with an oval shape have less reduction in strength, whereas the square is unfavourable. Tubular flange girders, even if perforated, provide flexural strength enhancement and a considerable reduction in material compared with plate flange girders. This section also behaves better in relation to carbon dioxide emissions.