Abstract

The research program is aimed at investigating the effectiveness of application of good ductile hybrid fiber reinforced polymer (FRP) to upgrade corroded RC beams. A total of 5 RC beams are tested under flexural load, the results show that compared with the un-strengthened corroded RC beam, the crack, yield, maximum and ultimate load of corroded RC beam strengthened with hybrid FRP sheets is increased by 14%, 35%, 102% and 109% respectively, and the displacement ductility factor is only decreased by 11%, which indicate that the hybrid FRP sheets can improve significantly the flexural performance of corroded RC beam.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.