Abstract
The experimental study of flammability limits of counterflow premixed methane-air flames in a planar micro channel is described in the paper. Combustion occurs in the gap between quartz plates which are connected with two countercurrent slot burners. The proposed counterflow burner allows investigation of the flame structure at low flow rates which are outside the applicability range of conventional counterflow burners at the normal gravity conditions. It was found that the heat return from combustion products to unburned mixture through the heat conducting plates is an essential effect at low gas flow rates.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.