Abstract

A system L consisting of two interconnected subsystems is considered, and local state vector feedbacks are applied to it. It is then proven that if the global system, and the local ones are controllable, E has no fixed modes. That these conditions cannot be relaxed, as well that this property cannot be generalized to more than two subsystems, is shown with some appropriate examples. †The results reported here were obtained while the authors were with the Fachgruppe fiir Automatik, ETH, Zurich

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.