Abstract

Percutaneous K-wire fixation is still a useful technique for closed oblique phalangeal and meta-carpal fractures when an adequate closed reduction can be achieved. Lag screw fixation may be the best choice for open fixation of long oblique phalangeal and metacarpal fractures. For short oblique fractures, plating or tension band wiring is recommended. Plating provide rigid fixation to allow early mobilization; however, one may encounter frequent complications such as extensor lag, stiffness, or joint contracture when plating technique is used in phalangeal fractures. Tension band wiring technique at the phalangeal location may reduce such complications. Overall, successful outcomes of treating phalangeal and metacarpal fractures require a clear appreciation of fracture anatomy and pattern. It is mandatory for the treating surgeon to be familiar with all the treatment techniques discussed in order to tailor a specific technique for a particular injury and patient type.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.