Eighty-two patients with 105 metacarpal and/or phalangeal fractures stabilized with plates were retrospectively reviewed to assess complications and outcomes. Despite stable fixation and early mobilization, major complications were encountered in 36% of fractures, especially with phalangeal and open fractures. Complications included stiffness, nonunion, plate prominence, infection, and tendon rupture. Forty-eight of 63 (76%) metacarpal fractures and 44 of 66 (67%) closed fractures had a final range of motion greater than 220 degrees; however, only 4 of 37 (11%) phalangeal fractures and 8 of 34 (24%) open fractures achieved this outcome. Despite technical advances in plate design and instrumentation, including lower-profile titanium plates, complications occur commonly with metacarpal and phalangeal fractures, leading to a high incidence of unsatisfactory results. We do not condemn plate fixation, and attribute many of our unsatisfactory results to the frequent use of plates in open and phalangeal fractures.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.