Abstract

This article presents a series of 10 fire resistance tests on steel columns built up from cold-formed steel (CFS) profiles. Relevant performance parameters such as load levels, restraint to thermal expansion, and encasing of the columns with fire protection material are used in this research. It is also presented a numeric, three-dimensional non-linear finite element model for simulating the behavior of these columns. The model was calibrated based on the experimental results. The fire resistance of the bare columns' tests did not exceed 10 min, however, this amount of time considerably increased, up to almost 90 min, for the columns with plasterboard hollow encasement. Plasterboard hollow encasement is presented as an alternative to increase the fire-resistance performance of built-up cold-formed steel columns.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.