Abstract

BackgroundSimulation of a left ventricle has become a critical facet of evaluating therapies and operations that interact with cardiac performance. The ability to simulate a wide range of possible conditions, changes in cardiac performance, and production of nuisances at transition points enables evaluation of precision medicine concepts that are designed to function through this spectrum. Ventricle models have historically been based on biomechanical analysis, with model architectures constituted of continuous states and not conducive to deterministic processing. Producing a finite-state machine governance of a left ventricle model would enable a broad range of applications: physiological controller development, experimental left ventricle control, and high throughput simulations of left ventricle function.MethodsA method for simulating left ventricular pressure-volume control utilizing a preload, afterload, and contractility sensitive computational model is shown. This approach uses a logic-based conditional finite state machine based on the four pressure-volume phases that describe left ventricular function. This was executed with a physical system hydraulic model using MathWorks’ Simulink® and Stateflow tools.ResultsThe approach developed is capable of simulating changes in preload, afterload, and contractility in time based on a patient’s preload analysis. Six pressure–volume loop simulations are presented to include a base-line, preload change only, afterload change only, contractility change only, a clinical control, and heart failure with normal ejection fraction. All simulations produced an error of less than 1 mmHg and 1 mL of the absolute difference between the desired and simulated pressure and volume set points. The acceptable performance of the fixed-timestep architecture in the finite state machine allows for deployment to deterministic systems, such as experimental systems for validation.ConclusionsThe proposed approach allows for personalized data, revealed through an individualized clinical pressure–volume analysis, to be simulated in silico. The computational model architecture enables this control structure to be executed on deterministic systems that govern experimental left ventricles. This provides a mock circulatory system with the ability to investigate the pathophysiology for a specific individual by replicating the exact pressure–volume relationship defined by their left ventricular functionality; as well as perform predictive analysis regarding changes in preload, afterload, and contractility in time.

Highlights

  • Every year since 1919, cardiovascular disease (CVD) accounted for more deaths than any other major cause of death in the United States [1]

  • Based on data collected by the National Health and Nutrition Examination Survey (NHANES), CVD was listed as the underlying cause of death in 30.8% of all deaths in 2014, accounting for approximately 1 of every 3 deaths in the U.S, while CVD attributed to 53.8% of all deaths in that year

  • The computational model effectively executed the trials assessing the performance of the finite state machine (FSM) architecture

Read more

Summary

Introduction

Every year since 1919, cardiovascular disease (CVD) accounted for more deaths than any other major cause of death in the United States [1]. Predictions indicate that by 2030, the total cost of CHF will increase almost 127% to an estimated $69.7 billion [1] This prediction is based on data that revealed that one-third of the U.S adult population has the predisposing conditions for CHF. The PV analysis was considered the gold standard for assessing ventricular properties, primarily due to the researched conducted by Suga and Sagawa [35,36,37]. This approach has failed to become the clinical standard for evaluating LV functionality due to the invasive nature of the procedure [14, 15]. Most recently are the efforts published in 2018 by Davidson et al with regard to the development of a beat-by-beat method for estimating the left ventricular PV relationship using inputs that are clinically accessible in an intensive care unit (ICU) setting and are supported by a brief echocardiograph evaluation [20]

Results
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.