Abstract
In this paper we investigate the electrical transient responses of a piezoelectric transformer (PT) under open-circuit operation and its response times. The transient responses are induced on both sides of the PT immediately after the AC voltage applied to the PT is switched off. An equivalent circuit with initial conditions is expressed first. Then, the equivalent circuit is used to derive an input voltage transient response and its response times. Moreover, an AC power supply system with a control switch is used to determine the transient responses, and an oscilloscope with a smoothing-and-filtering function is used to measure the transient responses and their DC components. Furthermore, the effects of load resistance, switching-off time and operating frequency on the transient responses are measured and discussed. From the measured results, the DC component of each output voltage transient response is almost zero and the AC response time of the output transient response is greatly decreased from 11.5 ms under an output open to 3.0 ms by adopting a 1 MΩ load resistance.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.