Abstract

To elucidate the usefulness of 3-dimensional anterior segment optical coherence tomography (3D AS-OCT) for bleb revision after trabeculectomy. Case series. Two patients who underwent trabeculectomy and subsequent bleb revision. Three-dimensional AS-OCT and intraoperative observation. AS-OCT and intraoperative observation were analyzed to identify the filtration openings on the scleral flap margin and leaking points. In 1 case with a leaking bleb, 3D AS-OCT examinations suggested the presence of numerous internal ostia (filtration openings). With 3D AS-OCT guidance, we carefully removed the leaking bleb with peripheral scar tissue. Histopathologic findings showed the presence of a thin bleb wall in the limbal conjunctiva corresponding to the point of aqueous leakage. In another case of an overhanging bleb, 3D AS-OCT examination revealed a thin bleb wall and multiloculated cystic structures. Histopathologic findings showed the presence of a thin region in the conjunctival epithelium in which connective tissue did not support the conjunctival epithelium, which seemed to correspond to the point at which oozing occurred. Three-dimensional AS-OCT enables evaluation of the internal morphology of filtration blebs and is useful for preoperative guidance for bleb revision.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call