Abstract

A sensitive method of CZE-ultraviolet (UV) detection based on the on-line preconcentration strategy of field-amplified sample injection (FASI) was developed for the simultaneous determination of five kinds of chlorophenols (CPs) namely 4-chlorophenol (4-CP), 2-chlorophenol (2-CP), 2,4-dichlorophenol (2,4-DCP), 2,4,6-trichlorophenol (2,4,6-TCP), and 2,6-dichlorophenol (2,6-DCP) in water samples. Several parameters affecting CZE and FASI conditions were systematically investigated. Under the optimal conditions, sensitivity enhancement factors for 4-CP, 2-CP, 2,4-DCP, 2,4,6-TCP, and 2,6-DCP were 9, 27, 35, 43, and 43 folds, respectively, compared with the direct CZE, and the baseline separation was achieved within 5min. Then, the developed FASI-CZE-UV method was applied to tap and lake water samples for the five CPs determination. The LODs (S/N=3) were 0.0018-0.019µg/mL and 0.0089-0.029µg/mL in tap water and lake water, respectively. The values of LOQs in tap water (0.006-0.0074µg/mL) were much lower than the maximum permissible concentrations of 2,4,6-TCP, 2,4-DCP, and 2-CP in drinking water stipulated by World Health Organization (WHO) namely 0.3, 0.04, and 0.01µg/mL, respectively, and thereby the method was suitable to detect the CPs according to WHO guidelines. Furthermore, the method attained high recoveries in the range of 83.0-119.0% at three spiking levels of five CPs in the two types of water samples, with relative standard deviations of 0.37-8.58%. The developed method was proved to be a simple, sensitive, highly automated, and efficient alternative to CPs determination in real water samples.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call