Abstract

Although widely used for field measurements of soil moisture, problems continue with the use of the neutron probe in clay soils comprised of over 40% clay fractions, and in the determination of the intensity of field sampling necessary to characterize a site. We examine issues associated with field practice and calibration, data analysis and estimation of variance, and error in soil moisture measurements for silty clay soils in the Imperial Valley, California, using large calibration data sets from several different layouts of neutron access tubes. Our analysis indicates that for field calibrations: (1) bulk density corrections of the count ratio data do not necessarily improve the standard errors of the water content measurements; (2) soil sampling for calibration within the access tube hole at the time of tube installation results in smaller measurement errors; (3) calibrations improve as the average soil moisture of the profile at the time of the original sampling decreases; and (4) field-wide calibrat...

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.