Abstract

Effect of nitrogen-implantation on electron field emission properties of amorphous carbon films has been examined. Raman and X-ray photoelectron spectroscopy measurements reveal different types of C–N bonds formed upon nitrogen-implantation. The threshold field is lowered from 14 to 4 V/μm with increasing the dose of implantation from 0 to 5 × 10 17 cm −2 and the corresponding effective work function is estimated to be in the range of 0.01–0.1 eV. From the perspective of tetrahedron bond formation, a mechanism for the nitrogen-lowered work function is proposed, suggesting that both the nitrogen nonbonding (lone pair) and the lone-pair-induced carbon antiboding (dipole) states are responsible for lowering the work function and hence the threshold field.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.