Abstract

Abstract. Measuring the chemical composition of airborne particulate matter (PM) can provide valuable information on the concentration of regulated toxic metals, support modelling approaches for source detection and assist in the identification and validation of abatement techniques. Undertaking these at a high time resolution (1 h or less) enables receptor modelling techniques to be more robustly linked to emission processes. This study describes a comprehensive laboratory and field evaluation of a high time resolution x-ray fluorescence (XRF) instrument (CES XACT 625) for a range of elements (As, Ba, Ca, Cd, Ce, Cl, Cr, Cu, Fe, K, Mn, Mo, Ni, Pb, Pt, S, Sb, Se, Si, Sr, Ti, V and Zn) against alternative techniques: high time resolution mass measurements, high time resolution ion chromatography, aerosol mass spectrometry, and established filter-based, laboratory analysis using inductively coupled plasma mass spectrometry (ICP-MS). Laboratory evaluation was carried out using a novel mass-based calibration technique to independently assess the accuracy of the XRF against laboratory generated aerosols, which resulted in slopes that were not significantly different from unity. This demonstrated that generated particles can serve as an alternative calibration method for this instrument.The XACT was evaluated in three contrasting field deployments; a heavily trafficked roadside site (PM10 and PM2.5), an industrial location downwind of a nickel refinery (PM10) and an urban background location influenced by nearby industries and motorways (PM10). The XRF technique agreed well with the ICP-MS measurements of daily filter samples in all cases with a median R2 of 0.93 and a median slope of 1.07 for the elements As, Ba, Ca, Cr, Cu, Fe, K, Mn, Ni, Pb, Se, Sr, Ti, V and Zn. Differences in the results were attributed to a combination of inlet location and sampling temperature, variable blank levels in filter paper and recovery rates from acid digestion. The XRF technique also agreed well with the other high time resolution measurements but showed a clear positive difference (slopes between 1.41 and 4.6), probably due to differences in the size selection methodology, volatility and water solubility of the PM in aerosol mass spectrometry (SO4) and ion chromatography (Ca, Cl, K and SO4), respectively.A novel filter analysis technique using the XACT showed promising initial results: filters analysed off-line with the XACT compared well to in situ XACT measurements with a median R2 of 0.96 and median slope of 1.07. The resulting range of slopes was comparable to slopes produced in the ICP-MS comparison. This technique provides an opportunity to use the XACT when it is not deployed in the field; thus expanding the potential use of this instrument in future studies.

Highlights

  • It has long been known that increased air pollution, particle pollution, is associated with adverse health effects (Brunekreef and Holgate, 2002; Kelly et al, 2012)

  • This study reports the field evaluation of the XACT at both traffic and industrial sites in the UK where it was compared to independent measurements of PM2.5 and PM10 on daily filters, analysed by inductively coupled plasma mass spectrometry (ICP-MS), and to alternative high time resolution chemical speciation instruments

  • The instrument samples with a volumetric flow rate of 1 m3 h−1 through an inlet tube heated to 45 ◦C when the ambient relative humidity (RH) exceeds 45 % to avoid water depositing on the tape

Read more

Summary

Introduction

It has long been known that increased air pollution, particle pollution, is associated with adverse health effects (Brunekreef and Holgate, 2002; Kelly et al, 2012). PM is not a homogenous air pollutant but rather a complex mixture; it varies in chemical and physical composition depending on the contributing sources and the atmospheric processes (AQEG, 2005). Even though they do not contribute substantially to the mass of PM, act as markers for specific source categories (Visser et al, 2015a) and evidence is emerging that some metals in ambient PM are associated with adverse health effects at concentrations near to current ambient levels (Chen and Lippmann, 2009)

Methods
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.