Abstract

Patients on left ventricular assist devices (LVAD) are prone to excessive hemostasis disturbances due to permanent contact of artificial pump surfaces with blood components. We aimed to investigate if fibrin clot permeability is altered in patients on long-term continuous-flow LVAD therapy and if the clot permeability is associated with clinical characteristics and adverse events. We investigated 85 end-stage heart failure patients (90.6% men, age 48.6-63.8years) scheduled for continuous flow long-term LVAD support according to current clinical indications. The patients were assessed periodically: prior to LVAD implantation (T1), 3-6months (T2) after LVAD implantation, 6-12months after (T3) and then every 6months. We tested the first three blood samples (T1-T3) and the last available blood sample (T4), but no longer than 5years after LVAD implantation. We assessed hemostasis parameters (Activated Partial Thromboplastin Time (APTT) Prothrombin Time, Activated Partial Thromboplastin Time, Fibrinogen, D-dimer, Antithrombin, Thrombin Time, Factor VIII, and von Willebrand Factor, aspirin-induced platelet inhibition, adenosine-diphosphate test) changes during the study period. Fibrin Clot Permeability was evaluated using a pressure system and Permeability Coefficient (Ks) was calculated. We observed a decrease in fibrin clot permeability (Ks) between T1, T2, T3 and T4 time periods; P < 0.01 for each comparison. Fibrin clot permeability was negatively correlated with fibrinogen concentration: r = -0.51, P < 0.001, factor VIII activity r = -0.42, P < 0.001. There was no association of Ks with age, Left Ventricular Ejection Fraction (LVEF) and medications P > 0.001, however cumulative measurements in patients on aspirin showed shortening of Ks in this group P = 0.0123. Major adverse cardiac and cerebrovascular events (MACCE) occurred in 36.5% patients, bleeding events in 25.9%, Net Adverse Clinical Events (NACE) in 62.4%; 31.7% patients died, and 17.6% underwent transplantation. The transplantation was considered as the endpoint. Discrepancies in Ks were observed between patients with MACCE, bleeding, and NACE, and patients without adverse events. Ks showed a constant trend towards normalization (P < 0.01) only in patients without adverse events. Patients with advanced heart failure have disturbed clot structure. A trend towards normalization of the Ks values is associated with fewer thromboembolic and bleeding complications in this group of patients.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.