Abstract
The application of shear stress sensors in structural health monitoring remains limited because current sensors are either difficult to implement, they feature a low measurement resolution or the interrogation of the output signal is complex. We propose to use fiber Bragg grating-based sensors fabricated in dedicated highly birefringent microstructured optical fibers. When embedded in a host material, the orientation angle of the fiber should be chosen such that their polarization axes are aligned parallel with the direction of maximum shear stress when the host is mechanically loaded. We present experimental results of sensors embedded in the adhesive layer of single lap and double lap structural joints. These tests demonstrate that when the joints are tension loaded, the embedded sensors have a shear stress sensitivity of around 60 pm/MPa. We study the influence of the adhesive material on the sensor response, as well as the influence of sensor orientation and location in the bond line. Finally, we demonstrate the minimal thermal cross-sensitivity of the shear stress sensitivity of this sensor.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.