Abstract

BackgroundCardiotocography (CTG) has high sensitivity, but less specificity in detection of fetal hypoxia. There is need for adjunctive methods easy to apply during labor. Low fetal heart rate short term variation (STV) is predictive for hypoxia during the antenatal period. The objectives of our study were to methodologically evaluate monitoring of STV during labor and to compare two different monitors (Sonicaid™ and EDAN™) for antenatal use.MethodsA prospective observational study at the obstetric department, Karolinska University hospital, Stockholm (between September 2011 and April 2015). In 100 women of ≥ 36 weeks gestation, STV values were calculated during active labor. In a subset of 20 women we compared STV values between internal and external signal acquisition. Additionally we compared antenatal monitoring with two different monitors in another 20 women.ResultsMedian STV in 100 fetuses monitored with scalp electrode during labor (EDAN™) was 7.1 msec (range 1.3–25.9) with no difference between early (3–6 cm) and late (7–10 cm) labor (7.1 vs 6.8 msec; p = 0.80). STV calculated from scalp electrode signals were positively correlated with delta-STV (STV internal –external) (R = 0.70; p < 0.01). No significant differences were found between Sonicaid™ and EDAN™ in antenatal external monitoring of STV (median difference 0.9 msec, Spearman Rank Correlation Sonicaid vs delta-STV; R = 0.35; p = 0.14).ConclusionsMedian intrapartum STV was 7.1 msec. Significant differences were found between internal and external signal acquisition, a finding that suggests further intrapartum studies to be analysed separately depending upon type of signal acquisition. Antenatal external monitoring with Sonicaid™ and EDAN™ indicates that the devices perform equally well in the identification of acidemic fetuses. Further studies are needed to assess the clinical value of intrapartum STV.

Highlights

  • Cardiotocography (CTG) has high sensitivity, but less specificity in detection of fetal hypoxia

  • In the lower distribution of short term variation (STV) (

  • We have presented single values of STV derived with a scalp electrode during labor with a median value of 7.1 msec

Read more

Summary

Introduction

Cardiotocography (CTG) has high sensitivity, but less specificity in detection of fetal hypoxia. Low fetal heart rate short term variation (STV) is predictive for hypoxia during the antenatal period. Cardiotocography (CTG) is often the method of choice in modern fetal monitoring [1,2,3]. Computerized interpretation can During the 1980ies Dawes and Redman [14,15,16,17,18] developed a method for antenatal computerized analysis in fetal heart rate monitoring (Sonicaid FetalcareTM, Huntleigh United Kingdom). A part of the SonicaidTM system is the computerized calculation of short-term-variation (STV), i.e. beat-to-beat variation, a function which cannot be interpreted visually. The technique has only been applied in antenatal testing using an ultrasound device to monitor the fetal heart rate

Objectives
Methods
Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call