Abstract
This study aims to assess the safety and efficacy of the fenestrated Anaconda device for the treatment of complex aortic aneurysms over 1 year in daily clinical practice. All patients who received the graft between October 2019 and October 2020 were prospectively enrolled in an observational, multicenter national registry. The primary endpoint was the aneurysm-related 1-year mortality rate. Secondary endpoints included all-cause mortality, technical success, device-related adverse events (AEs) and major complications, secondary reinterventions, endoleaks, target vessel (TV) outcomes, and a center-volume analysis comparing mortality and secondary reintervention rate between expert centers (>15 F/BEVAR per year) and nonexpert centers (≤15 F/BEVAR per year). Ninety-seven patients from 28 centers were treated. Aneurysms types included juxta-renal and short neck (84.6%), pararenal (5.2%), paravisceral (3.1%), and type IV thoracoabdominal (2.5%). Configurations with 1, 2, 3, and 4 fenestrations were used in 2, 12, 18, and 65 cases, respectively, totaling 350 TVs. Technical success was 98.0%, with 1 type Ic and 1 type IIIc endoleak. Mean follow-up was 468 days. Ten patients died, with 8 deaths (8.2%) due to non-aortic causes and 2 deaths (2.1%) from unknown causes. The estimated 1-year survival rate was 92.7% (95% CI: 87.8-98.1%). The reintervention rate at 30 days was 11.3% and the estimated reintervention rate at 1 year was 21.6% (95% CI: 12.7-29.6%). No type Ia endoleak occurred during follow-up. Three type III endoleaks occurred and required reintervention. Three TV occlusion occurred, yielding a 1-year TVI-free rate of 92.4% (95% CI: 89.4-99.3). No device-related major complication was recorded, and 3 device-related AEs occurred: 1 limb migration, 1 limb kinking and 1 limb thrombosis. There was no statistically significant difference in mortality and survival without reintervention between expert and nonexpert centers (Log rank p=0.52 and p=0.16, respectively). The fenestrated Anaconda device demonstrated acceptable early and at 1-year safety and efficacy for treating primarily juxta-renal and short-neck aortic aneurysms, in centers with varying levels of experience. The Anaconda Fenestrated, as the second commercially available custom-made device for complex endovascular aortic surgery, might adress some anatomical challenges. Following market authorization, this registry presents the 1-year outcomes of real-world device usage in a large number of centers, including small clinics. The results indicate that the device provided adequate efficacy and safety for treating mostly juxta-renal and short neck aneurysms, with notable improvement in technical success rate compared to older reports.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.