Abstract

Recently some researchers studied the frequency characteristics of a quartz crystal resonator (QCR) adhered with micro-particles to measure their physical and geometric parameters. Many researchers regard the particles as rigid spheres or consider the elasticity but ignore the contact deformation and contact area of the particles. In fact, the adhesion and vibration of soft particles are coupled together and the interaction is strong and complicated. In this paper, we separately simulated the adhesion and vibration of the particles using finite element method with ANSYS software. Through transmission line model of the QCR, we get the frequency shift induced by surface particles. We found larger, softer and heavier particles produce greater contact deformation and load impedance which cause greater frequency shift (negative). The obtained results can be applied into characterization of size and elastic modulus of micro-particulates.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.