Abstract

Cross-shaped concrete-filled steel tubular (CCFST) columns are used extensively in many infrastructural systems; however, the damage inside CCFST columns is difficult to inspect or monitor. This study develops a method based on embedded smart aggregates (SA) to monitor damage sustained by the concrete inside the CCFST column under low-frequency cyclic loading. Three CCFST columns with different width and wall thicknesses were fabricated and used as subjects to monitor the damage of the internal concrete using embedded piezoelectric SAs. Then, the measured piezoelectric signal undergoes wavelet packet analysis in order to be represented by a damage index (DI). The experimental outs show that the damage indices of the structure when exposed to low-frequency cyclic loading is basically consistent with the hysteretic and skeleton curves of the tested specimens, and is basically consistent with the observed experimental behavior. Overall, the results demonstrate the effectiveness of SAs in monitoring the formation of damage in the concrete inside CCFST.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.