Abstract

In this paper, a fault-tolerant predictive control (FTPC) is proposed for the post-fault operation of five-leg dual-mover primary permanent-magnet linear motor (PPMLM) drives with open circuit fault (OCF). In the post-fault operation, one phase winding and one voltage-source-inverter (VSI) leg are lost. As a result, there are four VSI legs and five healthy phase windings from two movers. Especially, one VSI leg is shared by two movers. The objects of FTPC are to reduce the computation burden and improve the performances. Firstly, A minimum copper loss principle is designed to distribute the reference current for two movers. Secondly, two global optimal mover voltage vectors (MVVs) for two movers are respectively determined by geometrical location. Thirdly, the two global optimal MVVs are respectively modified as two local optimal MVVs, in which the influence of the common leg is considered. Finally, two synthesized voltage vectors are obtained to improve the steady-state performances. Meanwhile, 60% of the computation burden can be reduced by using FTPC. The effectiveness of the proposed FTPC have been verified by experimental results.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.