Abstract

High-resistance connection (HRC) fault can result in increased copper loss, thus possibly causing damage to the electric machine drive system. Therefore, a fault-tolerant control strategy is proposed for a five-phase permanent magnet synchronous machine drive system with HRC to minimize the copper loss. The fault-tolerant control strategy is realized based on the magnetomotive force invariance principle and copper loss minimization principle. The simulation and experiment are carried out to quantitatively validate the effectiveness of the proposed fault-tolerant control strategy. Both the simulation and experimental results show that the proposed strategy can effectively reduce the copper loss caused by the HRC fault.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.