Abstract

Winding turn fault and high-resistance connection (HRC) fault will lead to different consequences and require different mitigation actions. In this study, the differentiating features between a turn fault and HRC fault are analysed and compared in a three-phase surface-mounted permanent magnet machine fed by the inverter with pulse-width-modulation voltages. The resultant high-frequency components in both voltages and currents are utilised for the fault detection and classification based on the high-frequency impedance and ripple current, without requiring modifications to the machine or interface design. Extensive simulations show that this method is capable of fault detection and classification in both transient and steady-state operations.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.