Abstract

In this paper, we present a fast and accurate thermal aware analytical placer. A thermal model is constructed based on a Green function with discrete cosine transform (DCT) to generate full chip temperature profile. Our thermal model is tightly integrated with an analytical placer implemented based on the SimPL framework. A temperature spreading force based on the Gaussian model is proposed to reduce the maximum on-chip temperature and optimize tradeoff between total half-perimeter wirelength and on-chip maximum temperature. The temperature profile generated using our thermal model is verified by the ANSYS ICEPAK and obtains an average deviation within 3.0% with $240\times$ speedup.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.