Abstract

In this study, three upflow column reactors were compared for anaerobic ammonium oxidation (Anammox) process start-up time with different ferrous iron concentration in feeding. Continuous experiments indicated that the start-up time of Anammox process could be shortened from 70 to 58d in R2 (0.06mM Fe2+) and 50d in R3 (0.09mM Fe2+). The Anammox activity appeared after 16days operation in R3. Quantitative PCR (q-PCR) analysis demonstrated a significant increase in quantity of Anammox bacteria in R3 compared with the other two reactors during entire operation. At the Fe(II) concentration of 0.09mM, the heme c levels inside Anammox cell and hydrazine dehydrogenase (HDH) activity increased dramatically, which could be the trigger of fast Anammox start-up.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.