Abstract

Sirius is the new 4th generation storage ring based synchrotron light source built and operated by the Brazilian Synchrotron Light Laboratory (LNLS). In this work, we report on the implementation at Sirius of a fast method for orbit response matrix (ORM) measurement which is based on sine-wave parallel excitation of orbit corrector magnets’ strength. This “AC method” has reduced the ORM measurement time from ∼ 25 minutes to 2.5–3 minutes and displayed increased precision if compared to the standard serial measurement procedure. When used as input to the Linear Optics from Closed Orbits (LOCO) correction algorithm, the AC ORM yielded similar optics corrections with less aggressive quadrupoles strength changes.