Abstract

The fast initial response (FIR) feature for cumulative sum (CUSUM) quality-control schemes permits a more rapid response to an initial out-of-control situation than does a standard CUSUM quality-control scheme. This feature is especially valuable at start-up or after a CUSUM has given an out-of-control signal. This article presents the average run length and the distribution of run length for CUSUM schemes with the FIR feature and compares FIR CUSUM schemes to standard CUSUM schemes. The comparisons show that if the process starts out in control, the fast initial response feature has little effect; however, if the process mean is not at the desired level, an out-of-control signal will be given faster when the FIR feature is used.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.