Abstract

Interleaved DC-DC boost converters are interesting choices in applications like fuel cells and photovoltaic systems. Although this converter offers low current ripple, but an open-circuit switch fault can lead to unacceptable current ripples. In this paper, a very fast and simple method is proposed to detect an open-circuit switch fault and its location. This method doesn't need any additional sensors, is efficient in CCM and DCM modes of operation, and can detect the fault in less than one switching period. Moreover, this method is suitable for implementation on an FPGA, due to the use of simple math and state machine blocks. Simulations are carried out to validate the effectiveness of this method.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call