Abstract
This paper presents an analysis of failure assessment diagram for PE4710 grade high density polyethylene pipes, which are recently concerned to use in the nuclear industry. Available test data of tensile, single edge notched tension specimens and pressurised pipes are summarised and suitably characterised for use in the failure assessment diagram in R6 procedure. Critical crack lengths and failure mode for the pressurised pipes and single edge notched tension specimens are determined under sustained load and compared with test results. Based on the concept of linear elastic fracture mechanics, a slow crack growth rate of PE4710 at 95°C is obtained excluding crack initiation time. To consider the effect of temperature on slow crack growth rate, a shift method is introduced. Remaining life is calculated against the crack margin and compared with the failure time.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.