Abstract
Reliability analysis is plagued by a lack of accurate data, leading to suboptimal parameter estimates and inaccurate decisions about replacement intervals and preventive maintenance activities. This paper discusses some of the problems associated with failure and maintenance data extraction from coal-fired power plant maintenance databases. Data from four generating units were observed for over 5 years and a reasonable number of equipment classes reviewed. The coal mills are identified as significant equipment that affects the availability of the generating units. This paper describes the interplay of events which includes failure modes, failure, repair and operating time. We investigate a database showing operation of coal mills, and give an exploratory data analysis in which we investigate engineering hypotheses related to mill operation. A competing risk probability model is proposed which captures some of the observed features of the systems under study.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.