Abstract
A fuzzy cognitive maps (FCM) application is proposed as a simple method to determine failure modes and effects of the standby liquid control system (SLC) during anticipated transient without scram (ATWS) in a boiling water reactor (BWR). The SLC has an important contribution to the total core damage frequency in a BWR. This is the first step in the development of an expert system that could involve many emergency systems of a BWR to simulate accident sequences, through the knowledge representation and reasoning with FCM designs in order to automate the decision making process. A simplified model of the SLC is analyzed with the fault tree analysis technique in order to compare this results with those obtained with the FCM and show consistency with the results, in order to see that both techniques show similar results even if the approaches are different.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.