Abstract

Based on macro morphology, metallographic microstructure, field emission scanning electron microscope observations and microhardness testing, failure analysis of the GCr15 steel balls in the ball screw pair was dealt with in this paper. The experimental results showed that small scratches and pits were evenly distributed on the surface of the A steel ball which showed features of wear failure. Characteristics of the B steel ball surface morphology were contacted to fatigue failure. Microstructure observation on the cross-section of the B steel ball showed that martensite and carbides were uneven distributed which were caused by the uneven elements distribution in the raw materials. It was the main cause of this abnormal failure. Therefore, the quality of the raw materials needed to be strictly controlled and the reasonable heat treatment process should be adopted to ensure the quality of the steel balls.