Abstract

Through methods, such as microscope analysis, chemical analysis, hardness analysis, metallography examination etc, the causes resulting in reheater tube cracking of 300MW station boiler have been analyzed. The result indicates this reheater tube cracking is reheat crack. The higher sensitive temperature in operating, excessive welding residual stress are the primarily inducement of cracking. In welding repair, the measures , such as replacing the material ,lower welding heat input, preheat treatment and so on, were taken. The welding repair succeeded greatly.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.