Abstract

Thermoluminescent (TL) glow-curves of 10 different coloured Toho Japan bead types have been obtained using a Risø TL/OSL reader studied for a fading period of 6 months as well as for residual dosimetry for fading up to 16 months after irradiation. For the entirety of the delay period studied the Frosted beads showed the largest TL response followed by Pink and Rose beads. Pink beads showed the best fit to the second order polynomial fit applied to the observed fading. In a more detailed dose curve fitted for a 6 month delay between irradiation and readout in order to determine the nature of the TL response as a function of increasing dose, it was found to follow the same trend for all bead colours. The residual TL response was also studied for beads that showed a large TL response. In these studies all colours showed similar dose response curves to those for the 1st readout, with Pink beads showing the best agreement to the fit applied to model fading.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.