Abstract

A new method of water nebulization for high-frequency jet ventilation (HFJV) using a coaxial saline infusion is described. A bench study was performed to investigate how alteration of the HFJV variables affects humidity using this method of humidification. The variables examined included the water flow rate (0.1, 0.25, 0.5, and 1.0 ml/min), cannula OD 2.1 mm (14 ga) and 1.4 mm (17 ga), ventilation rate (60, 80, 100, and 120 beat/min), inspiratory/expiratory (I/E) ratio (0.25, 0.67, and 1.5), and driving pressure (600, 900, 1200, and 1500 torr). Increasing water flow rate increased humidity. Humidity decreased with increased driving pressure, I/E ratio, and cannula OD. Humidity is not much affected by ventilation rate.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.