Abstract

Using two monomers of 4,4″-diamino-p-terphenyl and 1,3,5-triformylphloroglucinol, a co-precipitation structured magnetic covalent organic framework adsorbent was fabricated. After that, a high efficient vortex-assisted magnetic solid-phase extraction method was developed prior to gas chromatography-tandem mass spectrometry analysis for the determination of phthalate esters in milk samples. The fabricated magnetic adsorbent was facilely fabricated, fully characterized, and exhibited high extraction efficiency, which can be attributed to its larger pore size as well as strong hydrophobic and π-π stacking interactions between adsorbent and phthalate esters. Key parameters affecting extraction efficiency were investigated. Under the optimized conditions, the proposed method possessed good linearity (3.0-1000μg/L), high sensitivity (0.8-2.1 μg/L for limits of detection), and satisfactory recoveries (76.8-99.2%). The relative standard deviations for intra-day was 3.1-4.5% and inter-day was 3.3-6.1%. This work is suitable for high efficient separation/preconcentration of phthalate esters in milk samples.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.