Abstract
Recently, many groups have researched the reconstruction of bone tissue and the development of bone scaffolds using solid freeform fabrication technology. However, the capacity to produce three-dimensional hydroxyapatite (HA) scaffolds with a very accurate architecture is limited by difficulties in the manufacturing process. In this study, a HA scaffold with an accurate pore size of 300 ± 10 μm was fabricated using a microstereolithography (MSTL) system and molding technology. In addition, an agar-overlay test was performed to investigate the cytotoxicity of the fabricated scaffold.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.