Abstract

Many variables affect the pressure caused by splinting or casting. The purpose of this study was to compare pressure underlying a splint wrapped with either an elastic bandage or a bias cut stockinette. Thirty-two plaster volar resting splints were applied to a simulated extremity with a saline bag secured to it. A pressure transducer was connected to the saline bag to monitor changes in pressure once splints were applied, and 15 mL increments of saline were added to the bag to simulate swelling. Each dressing type was tested with normal application and tight application. Normal application splints wrapped with either bias cut stockinette or an elastic bandage demonstrated similar initial splint pressures (P = .81). With simulated swelling, splints wrapped with bias cut stockinette demonstrated a 15 mmHg (95% confidence interval [CI], 1.5-28.5) higher average pressure than those wrapped with an elastic bandage (P = .035). Tight application splints with an elastic bandage wrap demonstrated a 46 mmHg (95% CI, 16-77) higher initial splint pressure than those wrapped with bias cut stockinette (P = .009). Splints wrapped using either an elastic bandage or bias cut stockinette appear to have a similar safety profile, although in cases of excessive swelling, an elastic bandage may provide additional compliance. Tight splint application appears to be more hazardous with the use of an elastic bandage compared with a bias cut stockinette. Further study of the use of elastic bandages and bias cut stockinettes in the clinical setting may be warranted.