Sweep-frequency eddy current testing(ECT) is an efficient tool in nondestructive testing and evaluation due to its characteristics of non-contact, high sensitivity and abundant frequency information. In fact, the lift-off fluctuation is the main influencing factor to introduce the measurement errors. In this paper, the response signal feature, i.e. lift-off irrelevant frequency (LIF), has been found, which is immune to the effect of lift-off. Based on the characteristics, the sensor including two pairs of T-R coils is designed to obtain the feature point of LIF. Related analytical solutions and experiments are conducted to investigate the properties of LIF for non-magnetic materials, and the performance of LIF is also analyzed along with the conductivity and thickness of the tested piece. Hence, the LIF can provide the effective measurement of non-magnetic materials and immune to the lift-off fluctuation. The errors of thickness and conductivity measurement are 3.7% and 3.8% respectively.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.