Abstract

Limited data evaluated the outcomes of extracorporeal membrane oxygenation (ECMO) in patients with prosthetic valves. This study aimed to compare the outcomes of ECMO support for postcardiotomy cardiogenic shock in patients with mechanical versus bioprosthetic valves. This retrospective study included patients with ECMO support for postcardiotomy cardiogenic shock after valve replacement. Patients were grouped into bioprosthetic (n = 49) and mechanical valve (n = 22) groups. There were no differences in ECMO duration, inotropic support, intra-aortic balloon pump (IABP), stroke, duration of ICU, and hospital stay between groups. Postoperative thrombosis occurred in 2 patients with bioprosthetic valves (5.41%) and 2 with mechanical valves (14.29%), p = .30. All patients with thrombosis had central ECMO cannulation, concomitant IABP, and inotropic support during ECMO. All thrombi were related to the mitral valve. Three patients with thrombi had hospital mortality.Survival at 6, 12, and 36months for bioprosthetic valve patients was 30.88%, 28.55%, and 25.34% and for mechanical valves was 36.36% for all time intervals (Log-rank p = .93). One patient had bioprosthetic aortic valve endocarditis after 1year. Three patients with bioprosthetic valves had structural valve degeneration after 1, 2, and 5years. Outcomes of ECMO in patients with prosthetic valves are comparable between bioprosthetic and mechanical valves. Thrombosis might occur in both valve types and was associated with high mortality. ECMO could affect the long-term durability of the bioprosthetic valves.