Abstract

There is a strong need for techniques that can quantify the important reactive oxygen species hydrogen peroxide (H2O2) in complex media and in vivo. We combined chemiluminescence-based H2O2 measurements on a commercially available flow injection analysis (FIA) system with sampling of the analyte using microdialysis probes (MDPs), typically used for measurements in tissue. This allows minimally invasive, quantitative measurements of extracellular H2O2 concentration and dynamics utilizing the chemiluminescent reaction of H2O2 with acridinium ester. By coupling MDPs to the FIA system, measurements are no longer limited to filtered, liquid samples with low viscosity, as sampling via a MDP is based on a dynamic exchange through a permeable membrane with a specific cut-off. This allows continuous monitoring of dynamic changes in H2O2 concentrations, alleviates potential pH effects on the measurements, and allows for flexible application in different media and systems. We give a detailed description of the novel experimental setup and its measuring characteristics along with examples of application in different media and organisms to highlight its broad applicability, but also to discuss current limitations and challenges. The combined FIA-MDP approach for H2O2 quantification was used in different biological systems ranging from marine biology, using the model organism Exaiptasia pallida (light stress induced H2O2 release up to ~ 2.7 µM), over biomedical applications quantifying enzyme dynamics (glucose oxidase in a glucose solution producing up to ~ 60 µM H2O2 and the subsequent addition of catalase to monitor the H2O2 degradation process) and the ability of bacteria to modify their direct environment by regulating H2O2 concentrations in their surrounding media. This was shown by the bacteria Pseudomonas aeruginosa degrading ~ 18 µM background H2O2 in LB-broth. We also discuss advantages and current limitations of the FIA-MDP system, including a discussion of potential cross-sensitivity and interfering chemical species.

Highlights

  • Hydrogen peroxide (H2O2) is a reactive oxygen species (ROS) [1] and a strong oxidant, but due to its high activation energy H2O2 is relatively unreactive in comparison to other ROS [2]

  • We present the measuring characteristics of the combined microdialysis probes (MDPs)-based flow injection analysis (FIA) measurement of H2O2, and illustrate various measurements optimization steps regarding reagent concentrations, syringe pump speeds and choice of sample media

  • We demonstrate the application of the combined MDP-FIA system for minimally invasive measurements of H2O2 dynamics in almost real time

Read more

Summary

Introduction

Hydrogen peroxide (H2O2) is a reactive oxygen species (ROS) [1] and a strong oxidant, but due to its high activation energy H2O2 is relatively unreactive in comparison to other ROS [2]. The exact role of H2O2 is often not fully understood due to uncertainties in the determination of real concentrations in vivo [6] Some organisms such as algae [7] or human granulocytes (PMN) [8] release H2O2, while most cells and organism can sense and respond to H2O2 in their environment [5,9]. There is a strong need for methods that can quantify concentrations of H2O2 in vivo or under in vivo-like conditions with minimal sample manipulation Such measurements are paramount for our understanding of the processes regulating the release and degradation of H2O2 in different environmental and biomedical systems

Methods
Results
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.