Abstract
The experience of the extension of the proportional chambers lifetime at the HERMES (DESY) experiment is presented. A non-invasive technique against the aging process while continuously operating the detectors in the gap of the HERMES spectrometer magnet was performed. It was found that adding 0.14% water to the 65%Ar+30%CO 2+5%CF 4 gas mixture perfectly cancelled the appearance of self-sustained current (Malter effect). The studies of the remedy for the lifetime extension were performed with the test prototypes of the original proportional chambers. For the complete recovery of the aged test proportional chambers a special training method was developed as well. Training of the aged proportional chamber at 80%CF 4+20%CO 2 mixture glow discharge with reversed high voltage demonstrated a complete recovery of the detector.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.