Abstract

One of the prime components of a hot-wire (Cat) Chemical Vapor Deposition system is the filament used to pyro-catalytically crack the gases like silane. Burnt out tantalum filaments were studied to determine the possible improvement of lifetime for these filaments. The structure and chemical distribution in the filament were investigated, using electron microscopy and elemental analysis. It was found that at the high temperature centre section of a filament a thin surface silicide layer develops around a central metal core. At the filament ends a surface layer of metal silicide develops, that eventually consume the metal completely, causing breakages. Changes in the pre- and post-treatments of gas type and pressure were tested to improve the filament lifetime, arriving at a very simple procedure that increases the lifetime of the filament to several months. By annealing the hot filament both before and after a deposition run in a low pressure hydrogen ambient, a surface layer of pure silicon developed at the lower temperature ends, essentially protecting the metal from further silicidation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.