Abstract

We investigated the expansion of stacking faults (SFs) under a high current pulse stress in detail. In situ observations showed bar-shaped SFs and two types of triangle SFs with different nucleation sites. The calculated partial dislocation velocity of the bar-shaped SFs was four times faster than that of the triangle SFs. The temperature dependence of the partial dislocation velocity was used to estimate activation energies of 0.23±0.02 eV for bar-shaped SFs and 0.27±0.05 eV for triangle SFs. We also compared the electrical characteristics before and after the stress. The forward voltage drop slightly increased by 0.05 V, and the leakage current did not increase.