Abstract
In this paper, a sliding mode controller for the stator voltage amplitude of a stand-alone wound rotor synchronous generator is presented. The standard dq-model of the electrical machine connected to an isolated inductive load is obtained. Then, the control law is designed using sliding mode techniques. The controller introduces a dynamic extension so that the stator voltage amplitude has relative degree one. As a result, a fast controller, robust to both machine and load parameters variations, is obtained. The control algorithm, that does not requires the knowledge of the parameters, is implemented and validated experimentally.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: International Journal of Electrical Power & Energy Systems
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.