Abstract

Background and purposeWe report a systematic review of lung radiation doses from breast cancer radiotherapy. Methods and materialsStudies describing breast cancer radiotherapy regimens published during 2010–2015 and reporting lung dose were included. Doses were compared between different countries, anatomical regions irradiated, techniques and use of breathing adaptation. Results471 regimens from 32 countries were identified. The average mean ipsilateral lung dose (MLDipsi) was 9.0 Gy. MLDipsi for supine radiotherapy with no breathing adaption was 8.4 Gy for whole breast/chest wall (WB/CW) radiotherapy, 11.2 Gy when the axilla/supraclavicular fossa was irradiated, and 14.0 Gy with the addition of internal mammary chain irradiation; breathing adaptation reduced MLDipsi by 1 Gy, 2 Gy and 3 Gy respectively (p < 0.005). For WB/CW radiotherapy, MLDipsi was lowest for tangents in prone (1.2 Gy) or lateral decubitus (0.8 Gy) positions. The highest MLDipsi was for IMRT in supine position (9.4 Gy).The average mean contralateral lung dose (MLDcont) for WB/CW radiotherapy was higher for IMRT (3.0 Gy) than for tangents (0.8 Gy). ConclusionsLung doses from breast cancer radiotherapy varied substantially worldwide, even between studies describing similar regimens. Lymph node inclusion and IMRT use increased exposure, while breathing adaptation and prone/lateral decubitus positioning reduced it.

Highlights

  • Background and purposeWe report a systematic review of lung radiation doses from breast cancer radiotherapy

  • The average mean contralateral lung dose (MLDcont) for whole breast/chest wall (WB/CW) radiotherapy was higher for intensity modulated radiotherapy (IMRT) (3.0 Gy) than for tangents (0.8 Gy)

  • Radiation doses to the lungs from breast cancer radiotherapy were reported in 198 studies from 32 countries including 579 regimens (Fig. 1, Table 1, Tables E3,E4)

Read more

Summary

Introduction

We report a systematic review of lung radiation doses from breast cancer radiotherapy. Methods and materials: Studies describing breast cancer radiotherapy regimens published during 2010– 2015 and reporting lung dose were included. Doses were compared between different countries, anatomical regions irradiated, techniques and use of breathing adaptation. The average mean ipsilateral lung dose (MLDipsi) was 9.0 Gy. MLDipsi for supine radiotherapy with no breathing adaption was 8.4 Gy for whole breast/chest wall (WB/CW) radiotherapy, 11.2 Gy when the axilla/supraclavicular fossa was irradiated, and 14.0 Gy with the addition of internal mammary chain irradiation; breathing adaptation reduced MLDipsi by 1 Gy, 2 Gy and 3 Gy respectively (p < 0.005). For WB/CW radiotherapy, MLDipsi was lowest for tangents in prone (1.2 Gy) or lateral decubitus (0.8 Gy) positions. The highest MLDipsi was for IMRT in supine position (9.4 Gy)

Methods
Results
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.