Abstract
In the development of vibration condition monitoring technology of the movable reflector PO-3 of the IBR-2 research reactor with using S-discriminant vibration analysis [1], the paper presents data and results of a correlation assessment of the stochastic interrelationship degree between S-discriminant and spectral functions in various frequency bands over 8 years of operation of the installation. This made it possible to identify the main sources of vibration activity of units of neutron reflector, developing operational malfunctions of some of its bearings and their influence on changes in its vibration and technical condition.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.