Abstract

Behaviour factor values applicable to cross-laminated timber (CLT) buildings are determined and several variables influencing construction are examined. The necessary experimental tests and analytical interpretation for estimating the behaviour factors for CLT wall systems, characterised as they are by several types of layout, were performed. The information given in this paper may be used to estimate the behaviour factor of whole CLT buildings. The results show that the proposed q-factors confirm that construction design decisions affect the seismic responses of buildings, as opposed to single values applied to all CLT buildings. The experimentally based approach used here was applied to physical test data for five CLT shear-wall arrangements. The results may be applied to a wide range of design situations, as analyses of common CLT specimens and simple generalisation of this method can be extended to other systems and configurations.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.