Abstract

It has become a common practice to store sufficiently cooled spent nuclear fuel (SNF) assemblies in interim storage dry casks with passive cooling. These dry casks require nuclear safeguards monitoring because they contain plutonium. Past studies on dry cask modeling and simulations have shown that a remote monitoring system (RMS) situated inside the dry cask could continually monitor and detect the removal of even a single SNF assembly from the cask. This conceptual RMS design was tested by conducting laboratory-scale experiments using small-size 252Cf neutron sources. These small-size sources were surrounded by neutron-reflecting materials in the experiments to mimic the SNF assemblies as a surface neutron source to the fission chamber detectors of the RMS. Experimental and simulation results showed that the removal or diversion of even a single neutron source is detectable within 4 min with a probability of detection greater than 80%.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.